UPS uninterruptible power supply - discharge time calculation method-KEBO power supply

by:KEBO      2020-04-04
< p > active power load x support time = battery discharge capacity * UPS battery voltage inverter efficiency < / p > < p > a. Basic formula: < / p > < p > active power load x support time = battery discharge capacity * UPS battery voltage inverter efficiency < / p > < p > among them: the active power of load = the power factor of load by total power load < / p > < p > UPS inverter efficiency material 0. 9 < / p > < p > nominal capacity battery discharge capacity = x battery discharge efficiency < / p > < p > the battery discharge efficiency associated with discharge current and discharge time, can consult the table below to determine: < / p > < p > 1 < / p > < p > b. Formula: < / p > < p > active power load * support time = the battery discharge capacity * * UPS battery voltage inverter efficiency. < / p > < p > c。 Calculation example: < / p > < p > example: load 3000 va, total power load power factor is 0. 7, UPS battery voltage 96 v, request support for 1 hour, should choose the battery capacity. < / p > < p > : < / p > < p > 3000 ( VA) ×0. 7×1( h) = the battery discharge capacity x 96 x is 0. 9 < / p > < p > the battery discharge capacity = UPS ( VA) ×0. 7×1( h) X 0 / battery voltage. 9 < / p > < p > = nominal capacity battery discharge capacity/discharge efficiency < / p > < p > it is concluded that: the battery discharge capacity = 24. 3 ( Ah) < / p > < p > = 24 nominal capacity battery. 3/0. 6 = 40. 5 ( Ah) < / p > < p > result: 38 ah battery (optional 12 v / 38 ah battery 8) < / p > < p > in the UPS battery discharge should be constant power discharge, should load power at the mains is normal or not is not change. < / p > < p > the battery discharge current = ( The power factor of load of apparent power load x) /( X efficiency of inverter battery voltage) 。 The characteristics of the load of any changes will cause the change of discharge current. < / p > < p > UPS there is constant current discharge. Only when determining configuration batteries, battery parameters of some battery manufacturers only gives a constant current discharge parameters ( Because the battery of the same amount of definition is defined according to the constant current discharge) May use constant current discharge, when the parameters of < / p > < p > total power load * support the power factor of load time = nominal capacity battery * * UPS battery voltage discharge efficiency inverter efficiency < / p > < p > support time = ( Nominal capacity battery * * UPS battery voltage discharge efficiency inverter efficiency) /( The power factor of load by total power load) < / p > < p > nominal capacity battery = ( The power factor of load by total power load x support time) /( Discharge * UPS battery voltage inverter efficiency) < / p > < p > support time = ( AH * battery voltage discharge efficiency by 0. 9) /( KVA×0。 7) < / p > < p > nominal capacity battery = ( KVA×0。 7 x support time) /( * 0 battery voltage discharge efficiency. 9) < / p > < p > < / p >
Currently there is a global trend growing. People are more conscious about stabiliser for ac and are seeking alternatives to traditional solutions.
If you follow these straightforward steps you can keep your three phase voltage regulator stabiliser for ac. I think this article will help you make a wise decision on choosing the right .
Even Video are being made fine with advanced equipment.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...