Such replacement of UPS battery, battery life is longer

by:KEBO      2020-04-16
Such change UPS battery, the battery life longer replacement battery work has been completed, the multimeter monitor the total voltage of the battery, the battery pack is negative and neutral wire connection. Make sure the battery pack and UPS mainframe after all, closed the switch of battery pack, UPS uninterruptible power supply system returned to normal work. But sometimes we ignore a problem, how to properly change UPS battery, UPS working late to failure. To this end, the following detailed introduces the methods and steps of UPS battery replacement right. Prepare 1, first of all, to ensure the UPS host input power supply, the registration of new and old battery fire system inspection, the telecom room smoke sensor sealed, ready to carbon dioxide fire extinguishers and other related work. Before replace the battery to the host, the old battery, UPS battery monitor equipment completes the relevant registration record, especially the placement of each layer cell battery monitor terminal, do mark, draw a good connection. To ensure the effect after the battery replacement consistent with the original situation. 2, second, familiar with the site installation KEBO brand series UPS host battery back-up type for replacement work again, disconnect the connection between the host and battery switch, UPS UPS mainframe and disconnect the battery pack connection, ensure the safety of the staff when replace the battery. To remove the battery of original battery, battery replacement implementation engineers responsible for battery removal, the related auxiliary technical personnel for old and new battery handling work. In more complex point, if necessary, can take a picture, make sure that the replacement of the part. When dismantle old batteries, will remove the screw down the battery cable and battery terminal box place them neatly, to ensure that the engine rooms neat and clean. Old batteries after the break, the old battery and put in the position of the provisions in the battery holder. The scene after the convenient of finishing. Installing new battery frame assembly in a fixed position, and began to install the new battery at the same time, put new batteries in the battery rack, make the placement of the new batteries in the battery rack, adjust the best direction. After the fitting of a battery cable is rigid, check the battery terminals total check the battery voltage is normal, and so on and so forth, negative to connect the batteries are correct. After 3, the correct replacement battery, professional staff with a multimeter monitor the total voltage of the battery, the battery pack is negative and neutral wire connection. Make sure the battery pack and UPS mainframe after all, closed the switch of battery pack, UPS uninterruptible power supply system returned to normal work. Then detect UPS work voltage, current, charging voltage and working state and make the record. Observe the host by a person inside the liquid crystal display parameters and the actual are consistent, the parameters of battery time debugging, to ensure that the battery during the normal life won't appear the wrong alarm prompt. Disconnect the UPS UPS host debugging to normal after the host of the input power switch, simulation grid fault interrupt, test whether UPS system from the mains to battery backup power supply, to ensure normal operation of equipment within the room cabinet. After the completion of a battery replacement work, to clean the clean UPS room, clean up the sundry, ensures good UPS room environment. And should make new batteries to 24 hours, ensure that the new batteries full of power.
ZHONGSHAN DIANXING ELECTRICAL APPLIANCE INDUSTRY CO. LTD offers a ton of features and capabilities to help you acquire and retain customers, boost sales and manage contacts.
Our vision serves as the framework for our Video and guides every aspect of our business by describing what we need to accomplish in order to continue achieving sustainable, quality growth.
ZHONGSHAN DIANXING ELECTRICAL APPLIANCE INDUSTRY CO. LTD usees sentiment analysis to understand what their customers care about and leverage that information to reposition their products, create new content or even provide new products and services.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...